Parameter | Type | Required | Description |
---|---|---|---|
--comment | String | false | A comment describing the new device |
--configuration | Path | false | The path to the configuration file (environment variable: $WAXMILL_CONFIGURATION_FILE) |
--device-slot | Device Slot | true | The slot to which the device will be attached. |
--height | Integer | false | The framebuffer height |
--listen-address | String | false | The VNC server listen address |
--listen-port | Integer | false | The VNC server listen port |
--machine | UUID | true | The ID of the virtual machine |
--verbose | Log Level | false | Set the minimum logging verbosity level. |
--vga-configuration | VGAConfiguration | false | The guest VGA configuration |
--wait-for-vnc | Boolean | false | Will cause the machine to wait for a VNC connection before booting |
--width | Integer | false | The framebuffer width |
--replace | Boolean | false | true if an existing device in the given slot should be replaced. |
bus = ? [0 .. 255] ? ; slot = ? [0 .. 31] ? ; function = ? [0 .. 7] ? ; deviceSlot = bus , ":" , slot , ":" , function ; Examples: 0:0:0 255:31:7
ipv4Part = ? [0 .. 255]{1,3} ? ; ipv4 = ipv4Part , ".", ipv4Part , "." , ipv4Part , "." , ipv4Part , ; ipv6 = ? Any https://tools.ietf.org/html/rfc4291 IPv6 address ? ; name = ? Any host name ? ; address = ipv4 | ipv6 | name ; Examples: 127.0.0.1 [::1] [2600:1417:6000:198::255e] localhost www.example.com
$ waxmill vm-add-framebuffer-device \ --machine de17174a-1b3c-4ebc-80af-cb239aa18cbd \ --device-slot 0:4:0 \ --wait-for-vnc true \ --width 1024 \ --height 768 \ --listen-address [::1] \ --listen-port 5901 \ --vga-configuration OFF